SIDACtor
®
Protection Thyristors
2
Revised: 01/08/14
© 2014 Littelfuse, Inc.
Specifications are subject to change without notice.
Broadband Optimized™ Protection
MC Series - DO-214
Surge Ratings
Series
I
PP
I
TSM
50/60 Hz
di/dt
0.2x310
1
0.5x700
2
2x10
1
2x10
2
8x20
1
1.2x50
2
10x160
1
10x160
2
10x560
1
10x560
2
5x320
1
9x720
2
10x360
1
10x360
2
10x1000
1
10x1000
2
5x310
1
10x700
2
A min A min A min A min A min A min A min A min A min A min A/µs max
A 20 150 150 90 50 75 75 45 75 20 500
C 50 500 400 200 150 200 175 100 200
3
30 500
Package Symbol Parameter Value Unit
DO-214AA
T
J
Operating Junction Temperature Range -40 to +150 °C
T
S
Storage Temperature Range -65 to +150 °C
R
0JA
Thermal Resistance: Junction to Ambient 90 °C/W
Thermal Considerations
Notes:
1 Current waveform in µs
2 Voltage waveform in µs
3 For surge rating of P4500SCMCLRP 10x700µs min=150A
- Peak pulse current rating (I
PP
) is repetitive and guaranteed for the life of the product.
- I
PP
ratings applicable over temperature range of -40ºC to +85ºC
- The device must initially be in thermal equilibrium with -40°C < T
J
< +150°C
-8
-40 -20 020406080100 120140 160
-6
-4
0
2
4
6
8
10
12
14
Junction Temperature (T
J
) – °C
Percent of V
S
Change – %
25 °C
25°C
Case Temperature (T
C
) - ºC
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20 020406080100 120140 160
Ratio of
I
H
I
H
(T
C
= 25ºC)
Normalized V
S
Change vs. Junction Temperature
Normalized DC Holding Current vs. Case Temperature
50
100
0
t
r
t
d
0
Peak
Value
Half Value
t – Time (µs)
I
PP
– Peak Pulse Current – %I
PP
t
r
= rise time to peak value
t
d
= decay time to half value
Waveform = t
r
x t
d
V-I Characteristics t
r
x t
d